PEAK / A habit worth building
Are PEAK Saunas Safe? Third-Party EMF, ELF & VOC Testing
Third-party verified · By Austin Laudenslager, CEO, PEAK · Last verified November 18, 2026
Short answer: Yes. PEAK (Peak Saunas) saunas are third-party tested for EMF, ELF and VOCs. Vitatech Electromagnetics measured the magnetic field from PEAK heaters at under 0.2 mG at 3 inches and under 0.01 mG at 1 foot. VERT Environmental tested the air inside two PEAK production saunas with EPA Method TO-15. Every detected compound was below published health-based exposure limits.
Under 0.01 mG at 1 foot
Infrared heater magnetic field. Vitatech Electromagnetics, report VTE-3584, November 2026.
0.11 mG or less at 2 feet
Red light panel magnetic field. Vitatech Electromagnetics, report VTE-3584.
Every detected VOC below health limits
Cabin air, EPA Method TO-15. VERT Environmental and LA Testing (AIHA accredited), project 69163.
| Test | Independent lab | Result |
|---|---|---|
| EMF / ELF, infrared heaters | Vitatech Electromagnetics | Under 0.2 mG at 3 inches. Under 0.01 mG at 1 foot. |
| EMF / ELF, red light panel | Vitatech Electromagnetics | 0.11 mG or less at 2 feet. |
| Cabin air VOCs | VERT Environmental, with LA Testing (AIHA accredited) | All detected VOCs below OSHA, NIOSH and California health limits. |
| Benzene, styrene, xylene | LA Testing (AIHA accredited) | Not detected. |
Are PEAK saunas third-party tested for EMF and ELF?
Short answer: Yes. Vitatech Electromagnetics tested PEAK heating elements and the PEAK red light panel in November 2026. Every magnetic field reading was under 0.2 mG.
Vitatech Electromagnetics is an independent EMF engineering firm in Fredericksburg, Virginia. It is the same lab that other leading infrared sauna brands use. Vitatech tested the PEAK 120V infrared heater, the PEAK 240V infrared heater and the PEAK red light panel. The lab ran each test inside a magnetically shielded enclosure, so outside fields did not affect the readings.
- Lab: Vitatech Electromagnetics LLC
- Report: VTE-3584
- Date: November 2026
- Method: AC magnetic field, RMS, 10 to 3,000 Hz (the ELF band), with a laboratory-grade fluxgate magnetometer
- Units tested: PEAK 120V infrared heater, PEAK 240V infrared heater, PEAK red light panel
Full reports: get the signed lab reports by email.
What is ELF, and are PEAK saunas safe for ELF?
Short answer: Yes. ELF means extremely low frequency. It is the part of EMF that comes from household electric power, and it is the part a sauna heater produces. Vitatech measured the full ELF band, 10 to 3,000 Hz. The highest PEAK heater reading was 0.178 mG. The international public exposure guideline for 60 Hz magnetic fields is 2,000 mG (ICNIRP, 2010). The PEAK reading is more than 10,000 times below that guideline.
PEAK infrared heater magnetic field (mG)
| Distance from heater | 120V heater | 240V heater |
|---|---|---|
| 3 inches | 0.178 mG | 0.143 mG |
| 5 inches | 0.157 mG | 0.135 mG |
| 1 foot | Under 0.01 mG | Under 0.01 mG |
| 2 feet | Under 0.01 mG | Under 0.01 mG |
| 3 feet | Under 0.01 mG | Under 0.01 mG |
PEAK red light panel magnetic field (mG)
| Distance from panel | Red | Red + near-infrared | Near-infrared |
|---|---|---|---|
| 2 feet | 0.11 mG | 0.054 mG | 0.055 mG |
| 3 feet | 0.035 mG | 0.049 mG | 0.054 mG |
| 4 feet | 0.019 mG | 0.026 mG | 0.024 mG |
PEAK electric field (V/m)
Short answer: Vitatech also measured the electric field, 10 to 1,000 Hz. PEAK heaters read 14 to 51 V/m. The international public exposure guideline at 60 Hz is 4,167 V/m (ICNIRP, 2010). Every PEAK reading is under 1.5% of that guideline. The PEAK red light panel read under 1 V/m at every distance.
| Distance from heater | 120V heater | 240V heater |
|---|---|---|
| 3 inches | 51.04 V/m (1.2% of guideline) | 35.53 V/m (0.9% of guideline) |
| 5 inches | 46.5 V/m (1.1% of guideline) | 35.27 V/m (0.8% of guideline) |
| 1 foot | 41.91 V/m (1.0% of guideline) | 31.47 V/m (0.8% of guideline) |
| 2 feet | 25.84 V/m (0.6% of guideline) | 27.54 V/m (0.7% of guideline) |
| 3 feet | 14.13 V/m (0.3% of guideline) | 19.28 V/m (0.5% of guideline) |
The guideline is the ICNIRP 2010 reference level for the general public at 60 Hz: 4,167 V/m. Every PEAK reading is under 1.5% of it.
You sit about 3 to 12 inches from the heaters in a PEAK sauna. At those distances the measured field was 0.178 mG or less. For the science on EMF and health, read EMF and infrared saunas: the facts.
Are PEAK saunas third-party tested for VOCs?
Short answer: Yes. VERT Environmental sampled the air inside two PEAK production saunas in September 2026. An AIHA-accredited laboratory analyzed the samples. Every detected compound was below published health-based exposure limits.
- Sampling: VERT Environmental Testing & Consulting Services, San Diego, under a Senior Industrial Hygienist
- Analysis: LA Testing, Huntington Beach, an AIHA-LAP accredited laboratory
- Project: 69163
- Date: sampled September 7, 2026; report revised September 18, 2026
- Method: EPA Method TO-15, 6-liter Summa canisters, GC/MS, under legal chain of custody
- Units tested: two PEAK production saunas
What the lab found
- All detected VOCs were below OSHA permissible exposure limits.
- All detected VOCs were below NIOSH recommended exposure limits.
- All detected VOCs were below California Human Health Screening Levels.
- All detected VOCs were below California OEHHA chronic and acute reference exposure levels.
- Benzene, styrene, xylene, ethylbenzene, naphthalene, vinyl chloride and methylene chloride were not detected.
Detected compounds and exposure limits
| Compound | PEAK result (µg/m³) | Workplace exposure limit, OSHA or NIOSH (µg/m³) |
|---|---|---|
| Ethanol | 360 to 370 | 1,900,000 |
| Acetone | 74 to 80 | 2,400,000 |
| Isopropyl alcohol | 26 to 40 | 980,000 |
| Toluene | 10 to 12 | 750,000 |
| n-Butane | 6.8 to 10 | 1,900,000 |
| MEK (2-butanone) | 1.8 to 3.3 | 590,000 |
| Ethyl acetate | 1.9 to 2.1 | 1,400,000 |
| Chloromethane | 1.3 to 1.6 | 210,000 |
Every detected compound was more than 5,000 times below its workplace exposure limit. The lab tested for 97 compounds. It detected 8.
Total VOCs: The total of all detected compounds was 500 µg/m³ in each sauna. The lab report rates that level "Acceptable" on its indoor air scale. About three quarters of the total was ethanol.
"Not detected" means the level was below what the lab method can measure. The few compounds the lab did find are common in normal indoor air.
What is inside a PEAK sauna?
PEAK builds its cabins from solid wood. PEAK heaters use shielded wiring. Vitatech tested PEAK production infrared heaters at 120V and 240V. Vitatech tested PEAK’s full-body red light panel. Mini and Crown use different red light equipment.
Frequently asked questions
Are PEAK saunas low EMF?
Yes. Vitatech Electromagnetics measured PEAK heaters at 0.178 mG or less at 3 inches, and under 0.01 mG at 1 foot. Report VTE-3584, November 2026.
Are PEAK saunas low ELF?
Yes. Vitatech Electromagnetics tested PEAK heaters and the PEAK red light panel across the ELF band, 10 to 3,000 Hz. Every magnetic field reading was under 0.2 mG. The international public guideline at 60 Hz is 2,000 mG.
Who tested PEAK (Peak Saunas) saunas?
Vitatech Electromagnetics tested EMF and ELF. VERT Environmental sampled cabin air for VOCs, and LA Testing, an AIHA-accredited laboratory, analyzed the samples.
Do PEAK saunas off-gas harmful chemicals?
Independent air testing with EPA Method TO-15 found every detected VOC below OSHA, NIOSH and California health-based limits. Benzene, styrene and xylene were not detected.
Does the PEAK red light panel add EMF?
Very little. Vitatech measured the red light panel at 0.11 mG or less at 2 feet in all three modes.
Can I see the test reports?
Yes. Enter your email on this page and we will send you the signed Vitatech EMF reports and the VERT air quality report.
How does PEAK compare with other tested sauna brands?
PEAK uses the same independent labs and the same test methods as the other leading brands that publish results. PEAK heater readings of under 0.01 mG at 1 foot are among the lowest published figures for an infrared sauna heater.
Get the full lab reports
We will email you the signed Vitatech EMF reports and the VERT air quality report.